Technical parameters: | Venus 4000-S1 | Venus 5000-S1 | Venus 6000-S1 |
Battery specifications | |||
Battery type | lithium ion battery, lead-acid battery | ||
Battery rated voltage | 48 V | ||
Battery voltage range | 42-58 V | ||
Battery capacity recommended | 50-2000 Ah | ||
Maximum charging and discharging power | 4000 W | 5000 W | 5000 W |
Maximum charging current | 100 A (settable) | ||
Maximum discharging current | 100A (adjustable) | ||
Charging curve (lithium ion battery) | BMS | ||
Charging curve (lead-acid battery) | 3-stage adaptive maintenance | ||
Depth of Discharge | lithium ion battery: 0-90% adjustable, lead-acid battery: 0-50% adjustable | ||
Maximum DC power of single channel MPPT | 3500 W | ||
Maximum input voltage | 600 V | ||
Start-up input voltage | 100 V | ||
Rated input voltage | 360 V | ||
MPPT voltage range | 120 V- 580 V | ||
Full load DC voltage range | 200 V-520 V | 250 V-520 V | 300 V-520 V |
Number of independent MPPT | 2 | ||
Number of DC inputs | 1/1 | ||
Maximum input current | 13 A/13 A | ||
Maximum short circuit current | 18 A /18 A | ||
Maximum AC power | 4400 VA | 5500 VA | 6000 VA |
Maximum output current | 20 A | 25 A | 27.3 A |
Nominal grid voltage | L/N/PE, 220 VAC, 230 VAC, 240 VAC | ||
Nominal AC voltage range | 180 VAC-276 VAC (according to local standard) | ||
Rated grid frequency | 50 Hz/ 60 Hz | ||
Grid frequency range | 45 Hz-55 Hz/54 Hz-66 Hz (according to local standard ) | ||
Active power adjustable range | 0~ 100% | ||
Total harmonic component (current) | <3% | ||
Power Factor | 1 (+/-0.8 adjustable) | ||
Maximum output current | 18.2 | 22.7 | 22.7 |
Peak output power, time | 4800 VA,60 s | 6000 VA,60 s | 6000 VA,60 s |
Nominal output voltage, frequency | 220 V/230 V,50/60 Hz | ||
Voltage total harmonic distortion (@ linear load) | <3% | ||
Switching time | <10 ms | ||
European weighted efficiency | <97.20% | <97.30% | <97.50% |
Maximum charging and discharging efficiency of battery | <94.00% | ||
MPPT efficiency | >99.9% | ||
DC reverse connection protection | available | ||
Ground fault monitoring | available | ||
Over-current protection | available | ||
DC switch | available | ||
Battery soft start protection | available | ||
AFCI protection | optional | ||
Lightning protection | Class III |
Ambient temperature range | General parameters -30 ~ + 60 ℃ (Rating reduction occurs when the ambient temperate rises above 45 ℃.) |
Stand-by loss | <10 W |
Topology | high frequency isolation |
Degrees of protection | IP65 |
Relative Humidity range allowed | 0~ 100% |
Communication | CAN 2.0/RS 485, Wi-Fi/GPRS (optional) |
Protection level | Class I |
Maximum altitude for product operation | <4000 m |
Connection mode of current sensor | external |
Noise | <29 dB |
Weight | 27 kg |
Cooling mode | natural cooling |
Dimension (mm) | 540*380*185 |
Display | LCD & APP |
Warranty | 5 years (extendable) |
Standard | |
EMC | EN 61000-6-1, EN 61000-6-3 |
Safety regulations and standards | IEC62109-1,IEC62109-2 |
Grid-connection standard | IEC61727,IEC62116,IEC-61683,VDE-AR-N 4105, VDE V 0124-100,AS4777 |