Technical parameters: | Mercury 3680-S1 | Mercury 5000-S1 | Mercury 6000-S1 |
Input (DC) | |||
Maximum panel input power recommended | 4900 Wp | 7500 Wp | 9000 Wp |
Maximum DC power of single channel MPPT | 2400 W | 3000 W | 3150 W |
Maximum input voltage | 600 V | ||
Start-up input voltage | 120 V | ||
Rated input voltage | 360 V | ||
MPPT voltage range | 90 V-550 V | ||
Full load DC voltage range | 165 V-500 V | 175 V-500 V | 250 V-520 V |
Number of independent MPPT | 2 | ||
Number of DC inputs | 1/1 | ||
Maximum Input current | 13 A/13 A | ||
Maximum short circuit current | 18 A /18 A | ||
| |||
Rated output power | 3680 W | 5000 W | 6000 W |
Maximum output current | 16 A | 25 A | 27.3 A |
Nominal grid voltage | L/N/PE, 220Vac, 230Vac, 240Vac | ||
Nominal AC voltage range | 180 VAC-276 VAC (according to local standard) | ||
Rated grid frequency | 50 Hz/ 60 Hz | ||
Grid frequency range | 45 Hz-55 Hz/54 Hz-66 Hz (according to local standard) | ||
Active power adjustable range | 0~100% | ||
Total harmonic component (current) | <3% | ||
Power Factor | 1 (+/-0.8 adjustable) | ||
| |||
Efficiency | |||
Maximum efficiency | 97.60% | 97.80% | 98.00% |
European weighted efficiency | 97.20% | 97.30% | 97.30% |
MPPT efficiency | >99.9% | ||
available | |||
DC reverse connection protection | available | ||
Ground fault monitoring | available | ||
Over-current protection | available | ||
DC switch | available | ||
Battery soft start protection | available | ||
AFCI protection | optional | ||
Ambient temperature range -30 ~ + 60 ℃ (Rating reduction occurs when the ambient temperate rises above 45 ℃.) | |||
Stand-by loss | <10 W | ||
Topology | no transformer | ||
Degrees of protection | IP65 | ||
Relative Humidity range allowed | 0~100% | ||
Communication | RS 485, Wi-Fi/GPRS (optional) | ||
Protection level | Class I | ||
Maximum altitude for product operation | 2000 m | ||
Connection mode of current sensor | external | ||
Noise | <29 dB | ||
Weight | 11 kg | ||
Cooling mode | natural cooling | ||
Dimension (mm) | 380*380*150 | ||
Display | LCD & APP | ||
Warranty | 5 years (extendable) |
Standard | |
EMC | EN 61000-6-1, EN 61000-6-3 |
Safety regulations and standards | IEC62109-1,IEC62109-2 |
Grid-connection standard | IEC61727,IEC62116,IEC-61683,VDE-AR-N 4105, VDE V 0124-100,AS4777 |