Techniczne parameters: |
Venus 4000-S1 |
Venus 5000-S1 |
Venus 6000-S1 |
Battery specifications |
|||
Battery type |
lithium ion battery, lead-acid battery |
||
Battery rated voltage |
48 V |
||
Battery voltage range |
42-58 V |
||
Battery capacity recommended |
50-2000 Ah |
||
Maximum charging and discharging power |
4000 W |
5000 W |
5000 W |
Maximum charging current |
100 A (settable) |
||
Maximum discharging current |
100A (adjustable) |
||
Charging curve (lithium ion battery) |
BMS |
||
Charging curve (lead-acid battery) |
3-stage adaptive maintenance |
||
Depth of Discharge |
lithium ion battery: 0-90% adjustable, lead-acid battery: 0-50% adjustable |
||
Maximum DC power of single channel MPPT |
3500 W |
||
Maximum input voltage |
600 V |
||
Start-up input voltage |
100 V |
||
Rated input voltage |
360 V |
||
MPPT voltage range |
120 V- 580 V |
||
Full load DC voltage range |
200 V-520 V |
250 V-520 V |
300 V-520 V |
Number of independent MPPT |
2 |
||
Number of DC inputs |
1/1 |
||
Maximum input current |
13 A/13 A |
||
Maximum short circuit current |
18 A /18 A |
||
Maximum AC power |
4400 VA |
5500 VA |
6000 VA |
Maximum output current |
20 A |
25 A |
27.3 A |
Nominal grid voltage |
L/N/PE, 220 VAC, 230 VAC, 240 VAC |
||
Nominal AC voltage range |
180 VAC-276 VAC (according to local standard) |
||
Rated grid frequency |
50 Hz/ 60 Hz |
||
Grid frequency range |
45 Hz-55 Hz/54 Hz-66 Hz (according to local standard ) |
||
Active power adjustable range |
0~ 100% |
||
Total harmonic component (current) |
<3% |
||
Power Factor |
1 (+/-0.8 adjustable) |
||
Maximum output current |
18.2 |
22.7 |
22.7 |
Peak output power, time |
4800 VA,60 s |
6000 VA,60 s |
6000 VA,60 s |
Nominal output voltage, frequency |
220 V/230 V,50/60 Hz |
||
Voltage total harmonic distortion (@ linear load) |
<3% |
||
Switching time |
<10 ms |
||
European weighted efficiency |
<97.20% |
<97.30% |
<97.50% |
Maximum charging and discharging efficiency of battery |
<94.00% |
||
MPPT efficiency |
>99.9% |
||
DC reverse connection protection |
available |
||
Ground fault monitoring |
available |
||
Over-current protection |
available |
||
DC switch |
available |
||
Battery soft start protection |
available |
||
AFCI protection |
optional |
||
Lightning protection |
Class III |
Ambient temperature range |
General parameters -30 ~ + 60 ℃ (Rating reduction occurs when the ambient temperate rises above 45 ℃.) |
Stand-by loss |
<10 W |
Topology |
high frequency isolation |
Degrees of protection |
IP65 |
Relative Humidity range allowed |
0~ 100% |
Komunikacja |
CAN 2.0/RS 485, Wi-Fi/GPRS (optional) |
Protection level |
Class I |
Maximum altitude for product operation |
<4000 m |
Connection mode of current sensor |
external |
Noise |
<29 dB |
Weight |
27 kg |
Cooling mode |
natural cooling |
Wymiar (mm) |
540*380*185 |
Display |
LCD & APP |
Warranty |
5 years (extendable) |
Standard |
|
EMC |
EN 61000-6-1, EN 61000-6-3 |
Safety regulations and standards |
IEC62109-1,IEC62109-2 |
Grid-connection standard |
IEC61727,IEC62116,IEC-61683,VDE-AR-N 4105, VDE V 0124-100,AS4777 |