Technical parameters: |
Apollo 8000-T1
|
Apollo 10K-T1
|
Apollo 12K-T1
|
Apollo 15K-T1
|
Apollo 17K-T1
|
Apollo 20K-T1
|
Apollo 25K-T1
|
Apollo 30K-T1
|
Input parameters (DC) |
||||||||
Maximum panel input power recommended (kW) |
12 |
15 |
18 |
22.5 |
25.5 |
30 |
32.5 |
39 |
Maximum DC input voltage (V) |
1100 |
|||||||
Maximum input current of each MPPT (A) |
16 |
20 |
26 |
32 |
||||
Short circuit current of each MPPT (A) |
25 |
25 |
39 |
50 |
||||
Max.Power of each MPPT (kW) |
9.6 |
12 |
15.6 |
19.5 |
||||
No. of MPPT / strings |
2/1 |
2/2 |
2/2 |
2/2+3 |
||||
Start-up voltage (V) |
180 |
|||||||
MPPT Voltage range (V) |
160V~1000 |
|||||||
Full-load MPPT Voltage range (V) |
550~850 |
|||||||
Rated input voltage (V) |
600 |
|||||||
|
Output parameters (AC) |
|||||||
Rated output power (kW) |
8.8kW@40℃ 8kW@45℃ |
11kW@40℃ 10kW@45℃ |
13.2kW@40℃ 12kW@45℃ |
16.5kW@40℃ 15kW@45℃ |
18.7kW@40℃ 17kW@45℃ |
22kW@40℃ 20kW@45℃ |
27.5kW@40℃ 25kW@45℃ |
33kW@40℃ 30kW@45℃ |
Maximum apparent power (kVA) |
8.8 |
11 |
13.2 |
16.5 |
18.7 |
22 |
27.5 |
33 |
Max.output power (kW) |
8.8 |
11 |
13.2 |
16.5 |
18.7 |
22 |
27.5 |
33 |
Output connection type |
3W+PE or 3W+N+PE |
|||||||
Rated voltage/Voltage range (V) |
380/320~480 |
|||||||
Rated grid frequency |
45~55Hz / 55~ 65Hz (According to local grid standards) |
|||||||
Rated output current (A) |
12.2 |
15.2 |
18.2 |
22.8 |
25.8 |
30.4 |
38.0 |
45.6 |
Maximum output current (A) |
13.4 |
16.7 |
20.1 |
25.1 |
28.4 |
33.4 |
41.8 |
50.1 |
Power Factor (settable) |
> 0.99 @ full power (adjustable range: 0.8 leading ~ 0.8 lagging) |
|||||||
Total Harmonic Distortion THDi (full load) |
<3% (full load) |
|||||||
MPPT efficiency |
Efficiency 99.9% |
|||||||
Maximum efficiency |
98.4% |
98.5% |
98.6% |
98.6% |
||||
Euro. efficiency |
97.8% |
98.0% |
98.1% |
98.2% |
||||
China efficencty |
97.5% |
97.8% |
98.0% |
98.0% |
||||
DC switch with Shunt release |
Protection function Available |
|||||||
Output short circuit protection |
Available |
|||||||
Power grid fault monitoring |
Available |
|||||||
DC reverse connection protection |
Available |
|||||||
String monitoring |
Available |
|||||||
DC lightning protection |
type II |
|||||||
AC lightning protection |
type II |
|||||||
DC insulation impedance detection |
Available |
|||||||
AC leakage current detection |
Available |
|||||||
Over-temperature protection |
Available |
|||||||
DC component monitoring |
Available |
|||||||
DC fuse |
/ |
|||||||
Islanding detection |
Available |
|||||||
Smart IV diagnosis |
Available |
|||||||
Arc fault detection |
Optional |
|||||||
Bus voltage monitoring |
Available |
|||||||
PID repair and protection |
Optional |
|||||||
Low Voltage Ride Through |
Available |
|||||||
Arc fault detection |
Option |
|||||||
Remote upgrade and setup |
Available |
|||||||
anti-counterflow meter |
Available |
|||||||
Fault recorded |
Available |
|||||||
Nighttime SVG features |
Optional |
|||||||
Display mode |
Display and communication LED+bluetooth+APP |
|||||||
Communication mode |
RS485/4G/WIFI |
General parameters |
||
Dimension (mm)(W×H×D) |
430×380×180 |
|
Weight (kg) |
17 |
17 |
Operating temperature range |
-30℃~+60℃ (>45°Derating use) |
|
Cooling mode |
Air colling without fan |
Intelligent air cooling with Fan |
Maximum altitude for product operation |
4000m (>2000m Rating reduction occurs) |
|
Relative Humidity |
0~100% |
|
Input terminal |
MC4 (Amphenol) |
|
Output terminal |
OT/DT terminal(Max.50mm2 cable section) |
|
Degree of protection |
IP66 |
|
Self power consumption at night |
<1W |
|
Noise (dB) |
<35 |
<40 |
Topology |
no transformer |
Certification |
|
Standards |
NBT32004,IEC62109,IEC61727,IEC61683,IEC62116 |
Warranty |
5 Year Product Warranty, 10 Year Performance Warranty |